ScintCare Blue 755 Revolution 64-slices

The ScintCare Blue 755 is a versatile CT system for whole-body imaging, integrating the fully digital ScintiStar detector with multiple dose control technologies, including Nano Dose iterative algorithm to enable high-resolution dose-efficient scans. ScintCare Blue 755 is considered a thoughtful “green power” investment, due to its excellent power distribution management and low maintenance cost.

  • Digital ScintiStarÒ detector:

ScintCare Blue 755 incorporates an entirely digital integrated ScintiStar detector, which was solely developed by MinFound, from material to the whole structure design, based on the technical know-how of our skilled scientific team. The system produces high-resolution images with a well-managed radiation dose and an excellent signal-to-noise ratio.

  • Efficient dose management:

 

-NanoDose Iteration Algorithm (NDI)

NDI NanoDose Iteration Algorithm (NDI) is an innovative iterative technique for image reconstruction that takes full advantages of deep learning in anatomical structure in image space as well as model-driven iteration involving tube and detector in projection space, with the aim to generate sharp and high-resolution images at the lowest possible dose.

-ImA

Implemented imA technology enables the automated adjustment in the output of the tube according to the scanned anatomical region and patients’ size and weight, and therefore effectively reduces the X-ray dose while preserving the image uniformity of each slice image.

-70 kV Pediatric Protocol

ScintCare Blue 755 provides dedicated care for pediatric applications with 70 kV pediatric protocol, which effectively reduces the radiation while ensuring the quality of images.

Clinical application:

  • VR, MPR, CPR, SSD, MIP, MinP

Gantry:

  • Aperture: 70 см.
  • Gantry cooling: air
  • Gantry rotation: belt-driven
  • Slip ring type: low voltage
  • Positioning system: 3D lasers

HV Generator:

  • Power: 32 kW.
  • mA range: 10-300mA.
  • kV range: 70kV, 80kV, 100kV, 110kV, 120kV, 140kV

X-ray tube:

  • Anode heat storage capacity: 3.5 MHU
  • Heat dissipation rate of the tube: 735 KHU / min
  • Small focal spot size: 0.7 mm × 0.8 mm
  • Large focal spot size: 1.2 mm × 1.4 mm

 

Detector:

  • Number of detector rows: 32
  • Total number of detectors: 21 504

 

Patient table:

  • Maximum motion range: 1600 mm
  • Max horizontal speed of table top: 150 mm /sec
  • Motion tolerance in horizontal direction: ± 0.25 mm
  • Table elevation range: 440 mm
  • Max load capacity: 205 kg
  • Food pedal control table horizontal motion

Console:

  • UPS (3 KVA)
  • Memory: 32 GВ
  • Hard disk: 2 TB
  • Frequency: 3.6 GHz
  • Display: 1920 × 1200
  • DICOM 3.0 interface
  • Burn mode: DVD.
  • DICOM 3.0 print interface
  • DICOM 3.0 input and output interface
  • Auto filming
  • Automatic voice system and two-way voice transmission
  • Include: DICOM PRINT, DICOM STORE, DICOM QUERY, DICOM RETRIEVE, WORKLIST.
  • HIS, RIS and PACS interface
  • Raw data can be reconstructed on the workstation.

 

Scan and Image reconstruction:

  • Rotation time: 0.75 sec / 360°
  • Max single continuous spiral scan time: 100 s
  • Scout scan direction: anteroposterior, lateral
  • Pitch: 0.1 -00
  • Thinnest image slice thickness in 64-slice mode: 0,625 mm
  • Thinnest reconstructed slice thickness in 64-slice mode: 0.625 mm
  • Max slice number per rotation: 64
  • Nominal slice thickness for axial scan: 0.625 mm, 1.25 mm,5 mm,5mm,10 mm
  • Nominal slice thickness for helical scan: 0.625 mm, 1.25 mm,5 mm,5mm, 7.5 mm,10 mm
  • Parallel image processing
  • Simultaneous reconstruction: Can reconstruct and reorganize the image simultaneously with a variety of options. Different reconstruction options are available within the scan protocol.
  • FOV: 43 cm
  • Image reconstruction matrix: 1024 × 1024
  • Image display matrix: 1024 × 1024

           PDU:

  • Input voltage: 3-phase – 380V, 50Hz
  • Power: 50kVA

         Advanced software:

  • Beam hardening compensation
  • Posterior cranial fossa Image optimization
  • Motion artifact reduction
  • Children’s scanning protocol
  • NDI
  • Print film
  • Remote system maintenance

           Option: Workstation IntelliAtlas, standard configuration:

  • Windows 10 in English;
  • 24” LCD Display, 1920×1200;
  • Memory: 32GB;
  • Hard disk: 1 TB;
  • Basic functions including Patient Browser, Image Import, Query/Retrieve, Data Archiving, Archive to PACS, Archive to DVD, Archive to Local, DICOM Viewer, Viewing Patient Data, Patient Data Search Filtering and Sorting, Data Protection Modification and Deletion, Follow-up Data Management, Follow-up Imaging Comparison, Task Management
  • 2D Image browsing including Sequence Adjustment, Window Layout Adjustment, Toggle Tiled/Overlay, Multi-window Linkage Image Viewing, Cine, Scout Mode Viewing, DICOM Information Viewing, Window Width and Window Level Adjustment, Display or Hide Information, Images Panning Zooming Rotating Flipping Sharpening and Smoothing, Images Measurement (such as measuring distances, angles, area and so on) and Annotation
  • 3D Image browsing including Image VRT Reconstruction, Multi-mode Display of 3D Reconstruction Images, MPR, CPR, Multi-window Linkage Image Viewing, Multi-Mode MPR Display, Simulated Scalpel, One-click Removal of Patient Table, Tissue Extraction, Regional Growth, CTA One-click Bone Removal, Transparent Bone Display, Tissue Measurement, 3D Images Template, VE, 3D Images Add and Subtract, Images Measurement and Annotation, Window Width and Window Level Adjustment, Images Panning Zooming Rotating Flipping Sharpening and Smoothing, Sequence Saving, Keyframe Image Saving and Filming
  • Film Printing including Images Selection, Film Adjustment and Layout Settings, Multiple Film Sizes Selection, Printer Selection, Images Panning Zooming Rotating Flipping Window Width and Window Level Adjustment, Display or Hide Information, Images Measurement and Annotation, Printing Preview, eFilm, Printing Task Management, Status Display, Shortcut Key Settings
  • Report Function including Structured Report, Diagnosis Templates, Custom Diagnostic Template, Automatic Patient Information Import, Key Image Insertion, Report Preview, Report Editor, Report Printing, Saving Report in PDF;
  • Vascular Analysis including Head Neck Chest Abdomen Limbs Auto Bone Removal Protocols, Automatic Extraction Vascular, Head and Neck DSA Imaging, Automated Separation of Craniocervical Arteries and Veins, Automatic Extraction of Vascular Centerline, Multi-mode Display of Vascular like VRT MIP MinP SSD MPR, 2D Image, Rendering, 3D Images Clipping, Multi-point Vascular Tracking, Automatic Naming of Vascular, Arbitrary Angle Vascular CPR, Arbitrary Angle Vascular Straightening CPR, Position Linkage of Vascular Probes on Multi-dimensional Images, Vascular Stenosis Analysis, Vascular Plaque Analysis, Automatic Recognition of Vascular Contours, Vascular Virtual Endoscopy Playback and Video Recording, Stent Plan and Report.