H8 Portable Patient Monitor 

    • Most Popular Basic parameters (ECQ RESP, NIBP, Sp02, TEMP) to reach general clinical needs
    • Bright 12.1″ TFT display, easy to view
    • Arrhythmia and ST analysis to provide rapid cardiac diagnosis
    • Pitch tone to provide audibly recognized Sp02
    • Up to 480-hour trend to review previous patient data
  • Drug calculation and titration, useful clinical tools
  • NO Fan design suitable for night time operation and saving energy
TECHNICAL SPECIFICATION: 
 
Size and Weight
Size: 318mm х 264mm x 152mm
Weight: 4.5kg
Power supply
Power Voltage: AC 100-240V 50/60Hz
Power Input: 85VA
Safety class: Category I
Display
12.1″ Color TFT display
Resolution:800 x 600 pixels or higher
Battery
Type: Rechargeable Lithium battery
Operating time under the normal use and full charge: ≥120minutes
Thermal Recorder
Method: Thermal dot array
Paper width: 50mm (1.97 in)
Paper Speed:12.5/25/50(m single track or tri-track m/sec)
Traces: Single track or Tri-track
Alarm
Three Levels: Low, medium and high
Indication: Auditory and visual
Setup: Default and custom
Silence: All alarm can be silenced
Volume: 45-85 dB measured at meter
Storage Reviewing
Trend: 480-hour tabular and graphic trends data storage
NIBP: ≥2400 groups NIBP measurement data
ECG
Lead mode: 5-lead or 3-lead selectable
Lead selection: l;ll;lll; avR; avL; avF; Vx; CAL
Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
Accuracy: ± 1bpm or ± 1%, whichever is greater
Heart beat range: Adult: 15-300 bpm
HR
Range: Adult 10~300bpm
Pediatric & Neonate:10~350bpm
Refreshing time: ≤50 bpm Per2 pulses
50~~120bpm per 4 pulses ≥ 120bpm per 6 pulses
Resolution: 1 bpm
Accuracy: ±1% or ±1 bpm,whichever is greater
ST segment
Measurment range: – 2.0 mV~ 2.0mV
Resolution:0.01mV
RESP
Method: RA-LL impedance
Measurement range: Adult: 0~120rpm
Pediatric/neonatal: 0~150rpm
Apnea alarm: YES
NIBP
Method: Automatic oscillometry
Range of measurement:
Adult: 10~270mmHg
Child: 10~235mmHg
Neonate: 10~135mmHg
Accuracy: Static: ± 2% or ± 3mmHg,whichecer is greater
Unit: mmHg, kPa
Over-pressure protection: YES
Standard Sp02 (Digital)
Measurement Range:0~ 100%
Accuracy: At70~100%,±2%
At0~~69%, unspecified
PR
Measurement Range: 25~250bpm
Accuracy: ±1 % or ±1 bpm,whichever is greater
TEMP
Measurement Range: 25.0oC~50.0°C
Accuracy: ±0.2°C (exclusive of probe)
Unit: Celsius(°C),Fahrenheit(°F)
Connecting cable: Compatible with YSI-400 serial
Environment
Operating temperature:0~+40″C
Transportation and Storage temperature:-20″C to +50“C
Relative humisity: Working ≤85%
Transportation and storage ≤ 93%
Atmospheric pressure:860hPa to 1060hPa
Transportation and storage 500-1060 h
Standard configuration of H8:
ECG, HR, RESP, Sp02, NIBP, 1-TEMP, Lithium Battery
Optional parameter& configuration of H8:
2-TEMP, Thermal recorder, IBP,SideStream EtC02,Mainstream EtC02