We present to your attention the mobile digital X-ray system MobileCooper
Specification:
- X-ray High voltage generator.
· Standard output power: 40 kW.
· mA range: 10 – 500 mA.
· Tube voltage range: 40 – 150 kV.
· mAs range: 0.1 – 250 mAs.
· Load time range: 0.001 s ~ 6.3 s.
· High voltage output master frequency: 50 kHz ± 5%.
· High voltage transformer structure: The power frequency. - X-ray tube.
· Focus range: 0.6 / 1.2 mm.
· Anode heat capacity: 150 kHu.
· Anode type: Rotating anode, maximum speed: 3200 revolutions per minute.
· Tube sleeve heat capacity: 1250 kHu.
· The maximum voltage: 150 kV.
· The anode input power: Large focus: 50 kW; Small focus: 22 kW.
· Anode angle: 12°.
· The inherent filtration: 1.3 mm Al / 75 kV. - Collimator.
· The inherent filtration: 1.0 mm Al / 75 kV.
· The collimator is equipped with LED lights that turn off automatically after 30 s. · The collimator is built into measuring ruler. - The tube bracket structure.
· X-ray tube support way: Folding arm.
· Tube focus distance to the ground: 507 mm ~ 2000 mm, ± 5 %.
· Arm’s Folding Range: ± 60°.
· Tube Tilting Angle: ± 90°.
· Tube Vertical Rotation Angle: – 30° ~ + 90°.
· Collimator axial rotation: ± 360°. - Detector (iRay).
· WIFI connection, Amorphous Silicon, whole panel technology.
· Detector valid exposure size: 350 × 430 mm.
· Pixel size: 150 µm.
· Effective camera size of the detector: 350 × 430 mm.
· Gathering matrix: 2304 × 2800 pixels.
· Spatial resolution: 3.4lp / mm.
· Pixel gray level: 14 bit.
· Detector cooling mode: natural cooling. - Digital image workstation.
· CPU frequency: CORE i3.
· Memory capacity: 4GB.
· Hard drive capacity: 500 GB.
· Display size: 17 inch LCD touch screen.
· Display screen Maximum resolution: 1280 × 1024.
· 64 bit Windows operation system. - Image acquisition software.
· Patient registration: acquisition, find the patient data, to prepare for the examination.
· Radiographic examination:setting system parameters, exposure photography and get the image.
· Images display, image analysis, processing and output.
· Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0.
· Configure calibration: the system components such as flat-panel detector, such as tube for automatic configuration and calibration.
· System diagnosis: monitoring system status, diagnosis of the system fault.
· Image Printing: Image Output to Film Printer. - Battery.
· Lithium battery power supply.
· The rated capacity: 46.8 V, 10.8 Ah (Lithium battery meets UN38.3 standard requirements).
· Battery capacity: More than 200 exposures, chest image dosage (exposure conditions: 120 kv, 100 mA, 20 ms).
· Dual power supply,exposure under either wall current or lithium battery.
· Maximum charging 4 hours.
· Can support hand switch and remote control. - The machine parameters.
· Appearance size: 1560 mm × 650 mm × 1490 mm.
· Whole weight (no detector): 220 kg. - External interface.
· Display interface (DVI).
· Wireless network data transmission (WIFI).
· Cable network interface.
· USB (2). - Options.
· Chest rack.
· Moving flat bed. - Copyright certificates.
· DR service control application software.
· Mobile DR embedded system software.
· Mobile DR generator control software.
Warranty: 1 year.
Free hotline service.
Price: Best currently on the market. Please ask!
The system is doing well in the fight against Covid 19 around the world right now.