We present to your attention the mobile digital X-ray system MobileCooper

Specification:

  1. X-ray High voltage generator.
    · Standard output power: 40 kW.
    · mA range: 10 – 500 mA.
    · Tube voltage range: 40 – 150 kV.
    · mAs range: 0.1 – 250 mAs.
    · Load time range: 0.001 s ~ 6.3 s.
    · High voltage output master frequency: 50 kHz ± 5%.
    · High voltage transformer structure: The power frequency.
  2. X-ray tube.
    · Focus range: 0.6 / 1.2 mm.
    · Anode heat capacity: 150 kHu.
    · Anode type: Rotating anode, maximum speed: 3200 revolutions per minute.
    · Tube sleeve heat capacity: 1250 kHu.
    · The maximum voltage: 150 kV.
    · The anode input power: Large focus: 50 kW; Small focus: 22 kW.
    · Anode angle: 12°.
    · The inherent filtration: 1.3 mm Al / 75 kV.
  3. Collimator.
    · The inherent filtration: 1.0 mm Al / 75 kV.
    · The collimator is equipped with LED lights that turn off automatically after 30 s.    · The collimator is built into measuring ruler.
  4. The tube bracket structure.
    · X-ray tube support way: Folding arm.
    · Tube focus distance to the ground: 507 mm ~ 2000 mm, ± 5 %.
    · Arm’s  Folding Range: ± 60°.
    · Tube Tilting Angle: ± 90°.
    · Tube Vertical Rotation Angle: – 30° ~ + 90°.
    · Collimator axial rotation: ± 360°.
  5. Detector (iRay).
    · WIFI connection, Amorphous Silicon, whole panel technology.
    · Detector valid exposure size: 350 × 430 mm.
    · Pixel size: 150 µm.
    · Effective camera size of the detector: 350 × 430 mm.
    · Gathering matrix: 2304 × 2800 pixels.
    · Spatial resolution: 3.4lp / mm.
    · Pixel gray level: 14 bit.
    · Detector cooling mode: natural cooling.
  6. Digital image workstation.
    · CPU frequency: CORE i3.
    · Memory capacity: 4GB.
    · Hard drive capacity: 500 GB.
    · Display size: 17 inch LCD touch screen.
    · Display screen Maximum resolution: 1280 × 1024.
    · 64 bit Windows operation system.
  7. Image acquisition software.
    · Patient registration: acquisition, find the patient data, to prepare for the examination.
    · Radiographic examination:setting system parameters, exposure photography and get the image.
    · Images display, image analysis, processing and output.
    · Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0.
    · Configure calibration: the system components such as flat-panel detector, such as tube for automatic configuration and calibration.
    · System diagnosis: monitoring system status, diagnosis of the system fault.
    · Image Printing: Image Output to Film Printer.
  8. Battery.
    · Lithium battery power supply.
    · The rated capacity: 46.8 V, 10.8 Ah (Lithium battery meets UN38.3 standard requirements).
    · Battery capacity: More than 200 exposures, chest image dosage (exposure conditions: 120 kv, 100 mA, 20 ms).
    · Dual power supply,exposure under either wall current or lithium battery.
    · Maximum charging 4 hours.
    · Can support hand switch and remote control.
  9. The machine parameters.
    · Appearance size: 1560 mm × 650 mm × 1490 mm.
    · Whole weight (no detector): 220 kg.
  10. External interface.
    · Display interface (DVI).
    · Wireless network data transmission (WIFI).
    · Cable network interface.
    · USB (2).
  11. Options.
    · Chest rack.
    · Moving flat bed.
  12. Copyright certificates.
    · DR service control application software.
    · Mobile DR embedded system software.
    · Mobile DR generator control software.

Warranty: 1 year.
Free hotline service.

Price: Best currently on the market. Please ask!
The system is doing well in the fight against Covid 19 around the world right now.